COREXTION · Nuclear power, COREX microreactors, CAIRN pebble-bed modules, ONYX fuel

Conceptual design stage · Simulation-driven · COREX · ONYX · CAIRN

Nuclear power from the edge of the grid to the grid itself.

Two reactor lines on one simulation-first platform. COREX heat-pipe microreactors, 100 kWe to 1.2 MWe, for remote sites. CAIRN helium-cooled pebble-bed modules, 20 to 80 MWe each, fueled by ONYX, our denser and tougher coated-particle fuel.

100 kWe – 1.2 MWe
COREX family electric output — custom designs to 5 MWe
0
Pumps, valves, or pressurized loops in the primary system
0 L
Water required on site — fully air-cooled
5–8 yr
Sealed-core life targets between factory refuelings
1 truck
ISO-class transport envelope per unit

All figures are design targets for the conceptual COREX family, derived from modeling and simulation. No COREX unit has yet been built or tested.

Mission

The most expensive electricity on Earth is diesel at the end of a supply chain.

Every remote mine, arctic village, island grid, radar station, and forward operating base pays it — in dollars, in emissions, and sometimes in lives.

Remote Alaskan communities pay $0.50 to over $1.00 per kWh for diesel power. Fully accounted off-grid diesel — fuel, transport, and maintenance — commonly runs $0.80–$1.00/kWh. For the military, the fully burdened cost of fuel delivered to a contested theater has been estimated at hundreds of dollars per gallon, and U.S. Army data from Iraq and Afghanistan attributed roughly one casualty to every 24 fuel resupply convoys.

Our mission is to replace that lifeline with sealed, solid-state nuclear units that arrive on one truck, run for years on a single core, and leave nothing behind when they're done.

Technology · Solid-state core

A reactor with no moving parts at its heart.

A COREX core is a solid metal monolith threaded with fuel channels and hundreds of sealed sodium heat pipes. Fission heat leaves the core the way heat leaves a spacecraft — passively, silently, with nothing to pump, pressurize, or break.

CORE · EVAPORATOR SHIELD · ADIABATIC HEAT EXCHANGER · CONDENSER sodium vapor → carries latent heat ← liquid returns by capillary wick — no pump fission heat in heat to power conversion
FIG.01 — One sealed sodium heat pipe. Evaporation, vapor flow, condensation, capillary return: a closed loop with zero moving parts, driven only by the temperature difference itself. A COREX core uses hundreds of them in parallel — if one pipe fails, its neighbors simply carry the load.
01 · Passive heat removal

No pumps. No valves. No LOCA.

The core is solid — there is no circulating primary coolant to lose, so the loss-of-coolant accident class that dominates conventional reactor safety is designed out entirely. The system is designed to operate near atmospheric pressure.

02 · Self-regulating physics

Walk-away safe by design

The core is designed with a strong negative temperature coefficient so that it throttles itself: as temperature rises, reactivity falls. Decay heat is designed to be removed passively by conduction, natural convection, and radiation — no operator action, no AC power, no water.

03 · Fuel

TRISO — each particle its own containment

Poppy-seed-sized HALEU fuel particles (enriched below 20%) wrapped in ceramic layers engineered to retain fission products beyond 1,600 °C — a fuel form backed by decades of DOE testing and reactor operating experience going back to the 1960s.

04 · Control

Drums out, rods in

Reactivity is managed by rotating control drums around the core — absorber on one face, reflector on the other — with independent shutdown rods that stay locked in throughout transport.

05 · Power conversion

Stirling to Brayton, by scale

Free-piston Stirling engines at the 100 kWe class; compact supercritical-CO₂ Brayton from the 400 kWe class up. Air-cooled heat rejection — zero site water, from the Arctic to the equator.

06 · Heritage

Built on proven physics

NASA and NNSA's KRUSTY test (2018) ran a sodium-heat-pipe reactor at full power — riding through simulated heat-pipe and engine failures on physics alone. COREX builds on that demonstrated physics — an architecture now being actively pursued across the industry.

Anatomy of a COREX unit

Select a system to explore the architecture.

ISO TRANSPORT ENVELOPE — SEALED, FACTORY-FUELED SHIELD ASSEMBLY CORE MONOLITH control drums SODIUM HEAT PIPES ×100s passive heat transport — no pumps HEAT EXCHANGER GEN sCO₂ BRAYTON PCU grid-ready power out ambient air in warm air out gravel pad — minimal site preparation by design
FIG.02 — Conceptual architecture of a MWe-class COREX unit (illustrative, not to scale). Heat flows left to right: solid core → sodium heat pipes → heat exchanger → sCO₂ turbine-generator → ambient air. Nothing circulates through the core but heat itself.
Core monolith

A solid block threaded with TRISO fuel channels and heat-pipe bores. No coolant flows through it — heat conducts to the pipes, and the block's thermal mass buffers transients.

The COREX family

One architecture. Sized to your site.

Every COREX shares the same solid-state heat-pipe core — scaled, configured, and shielded around your load profile. Three baseline classes, plus a bespoke design service for everything from 50 kWe to 5 MWe.

Scout class

COREX-100

100 kWe
  • ≈350 kWt thermal output
  • Free-piston Stirling conversion
  • Single 20-ft ISO envelope
  • 5-year sealed-core life target

EXPLORATION CAMPS · TELECOM & RADAR SITES · DISASTER RESPONSE

Station class

COREX-400

400 kWe
  • ≈1.3 MWt thermal output
  • sCO₂ Brayton conversion
  • 40-ft ISO envelope
  • 6-year sealed-core life target

MINE CAMPS · ISLAND MICROGRIDS · OFF-GRID INDUSTRY

Frontier class · flagship

COREX-1200

1.2 MWe
  • ≈3.5 MWt with cogeneration heat
  • sCO₂ Brayton conversion
  • 40-ft envelope + support module
  • 8-year sealed-core life target

PRODUCING MINES · DEFENSE INSTALLATIONS · LARGE ISLAND GRIDS · DISTRICT HEAT

Bespoke

COREX-C

50 kWe – 5 MWe
  • Your load profile becomes a reactor
  • Parametric digital-core sizing
  • Site-matched shielding & transport
  • Heat, power, or both

CUSTOM ENVELOPE · COGENERATION · DESALINATION · HYBRID MICROGRIDS

COREX family — design targets (conceptual design, modeling & simulation basis)
ParameterCOREX-100COREX-400COREX-1200
Electric output100 kWe400 kWe1.2 MWe
Thermal output≈350 kWt≈1.3 MWt≈3.5 MWt
Core coolingSodium heat pipes — solid-state, passive, redundant
FuelTRISO particles, HALEU <20% enrichment, factory-sealed core
Power conversionStirling arraysCO₂ BraytonsCO₂ Brayton
Core life target5 yr6 yr8 yr
Refueling modelSealed core returns to factory — no on-site fuel handling, no waste left on site
Site waterNone — air-cooled heat rejection
Transport20-ft ISO40-ft ISO40-ft + support module
Transport modeTruck, rail, or barge — shutdown rods locked in, passive decay-heat rejection in transit
TurndownDesigned for load-following operation across remote microgrid profiles

Design targets, not measured performance. The COREX family is in the conceptual design stage; figures derive from our simulation campaigns and from published reference designs in the 100 kWe–5 MWe heat-pipe class, and will be refined through preliminary design and testing.

ONYX fuel · Coated-particle pebble fuel

ONYX. A denser, tougher coated-particle fuel.

Every ONYX pebble holds about 17,500 independent ceramic pressure vessels, each sealing its own speck of fuel. ONYX gives each one a denser uranium-nitride kernel and two carbide shells, and wraps the whole pebble in silicon-carbide armour.

UN kernel · 99.5% N-15 Ø 425 µm · 19.75% U-235
FIG.03 · ONYX coated particle, to scale (Ø 895 µm). From the centre: uranium-nitride kernel, porous carbon buffer, inner pyrocarbon, zirconium-carbide barrier, silicon-carbide barrier, outer pyrocarbon.
  • Kernel · UN, 99.5% N-15425 µm · 12.8 g U/cm³

    Uranium nitride packs 12.8 g of uranium into each cubic centimetre, among the densest ceramic fuels. Nitrogen-15 is required: natural nitrogen absorbs neutrons and breeds carbon-14.

  • Buffer · porous carbon100 µm

    Holds fission gas and absorbs kernel swelling and fission-fragment recoil.

  • Inner pyrocarbon40 µm

    Seals the kernel and gives the ceramic layers a smooth substrate.

  • Zirconium carbide · new barrier20 µm

    A second carbide shell that resists palladium attack and keeps its strength far above SiC limits. It sits inside the SiC, protected from air.

  • Silicon carbide35 µm

    The proven pressure vessel and fission-product barrier of coated-particle fuel.

  • Outer pyrocarbon40 µm

    Protects the SiC and bonds the particle into the graphite matrix.

Kernel

More uranium per particle

The nitride kernel lets one pebble carry 9.0 g of uranium in 17,499 particles. Each pebble delivers about 2.00 MWd of heat before it is retired.

Barriers

Two carbide shells

ZrC inside SiC gives each particle a second ceramic pressure boundary and a second fission-product barrier. If one shell has a defect, the other still holds.

Pebble

SiC-armoured surface

A 0.5 mm silicon-carbide skin on the 60 mm pebble is designed to slow graphite oxidation if air or steam ever enters the core, and to cut graphite dust from pebble-on-pebble wear.

ONYX pebble · design point and OpenMC results (60 mm pebble, 900 K)
ParameterONYXBasis
KernelUN, 99.5% N-15, Ø 425 µm, 12.8 g U/cm³Design
Enrichment19.75 wt% U-235 (HALEU)Design
Uranium per pebble9.0 g (1.78 g U-235)OpenMC model bookkeeping
Particles per pebble17,499 · Ø 895 µmOpenMC model bookkeeping
Ceramic barriers per particle2 (ZrC + SiC) plus 3 carbon layersDesign
Pebble surface0.5 mm SiC armourDesign
Infinite-lattice k, fresh1.4763 ± 105 pcmOpenMC, explicit particles
Discharge burnup≈220 MWd/kg uraniumOpenMC depletion + CAIRN-80 leakage
Heat delivered per pebble2.00 MWdBurnup × uranium
Spent pebbles per year, CAIRN-8032,844200 MWt, 90% capacity factor
Fuel temperature coefficient+2.89 ± 0.24 pcm/KOpenMC, 900→1,200 K
Natural-nitrogen penalty−887 pcmWhy N-15 is required

ONYX is a COREXTION design concept. It has not yet been fabricated or irradiated; the figures above come from our simulations.

What ONYX still has to prove

  • Nitrogen-15 at 99.5% purity costs far more than natural nitrogen today. Recycling it from spent kernels is part of the plan.
  • Uranium nitride reacts with hot steam if a particle fails. The two carbide shells and the armoured pebble exist to keep that from happening.
  • Zirconium carbide has a much thinner irradiation record than SiC. ONYX needs an AGR-style irradiation and heating campaign.
  • A SiC skin on graphite must survive thermal-expansion mismatch over years of cycling. That is a materials test before it is a design claim.

CAIRN series · Pebble-bed modules

CAIRN. Pebble-bed power, sized to the load.

A cairn is a pile of stones that marks the way. A CAIRN module is a helium-cooled bed of ONYX pebbles that keeps itself cool after shutdown with no pumps, no water and no operator action. Three module sizes cover 20 to 80 MWe each, and units combine into plants for larger demand.

STEEL VESSEL ONYX PEBBLE BED graphite reflector control rods pebbles recirculate helium in · 260 °C · 6 MPa helium out · 750 °C STEAM GENERATOR 565 °C steam turbine-generator · ≈40% or process heat
FIG.04 · CAIRN module flow path (illustrative, not to scale). Cold helium rises along the reflector, flows down through the pebble bed and leaves hot to a steam generator. Pebbles move slowly down the bed, are measured for burnup at the bottom, and return to the top until they reach their discharge burnup.
District class

CAIRN-20

20 MWe
  • 50 MWt · helium 750 °C
  • Bed Ø 2.2 m × 3.3 m
  • ≈68,000 ONYX pebbles
  • ≤1,278 °C peak fuel, no cooling

MINES · ISLANDS · DATA CENTRES · DISTRICT HEAT

Industrial class

CAIRN-50

50 MWe
  • 125 MWt · helium 750 °C
  • Bed Ø 2.6 m × 6.0 m
  • ≈172,000 ONYX pebbles
  • ≤1,483 °C peak fuel, no cooling

PROCESS STEAM · DESALINATION · REGIONAL GRIDS

Utility class · flagship

CAIRN-80

80 MWe
  • 200 MWt · helium 750 °C
  • Bed Ø 2.8 m × 9.5 m
  • ≈316,000 ONYX pebbles
  • ≤1,490 °C peak fuel, no cooling

COAL-PLANT REPLACEMENT · 4-PACK = 320 MWe

CAIRN series · conceptual design point (modeling and simulation basis)
ParameterCAIRN-20CAIRN-50CAIRN-80
Thermal power50 MWt125 MWt200 MWt
Electric output (≈40%)20 MWe50 MWe80 MWe
Pebble bedØ 2.2 m × 3.3 mØ 2.6 m × 6.0 mØ 2.8 m × 9.5 m
Core power density4.0 MW/m³3.9 MW/m³3.4 MW/m³
Pebbles in core67,659171,817315,506
Uranium in core0.61 t1.55 t2.84 t
k-eff, fresh core, rods out (OpenMC)1.3036 ± 81 pcm1.3522 ± 90 pcm1.3706 ± 84 pcm
Side-reflector rod bank worth (OpenMC)9,383 pcm7,489 pcm6,703 pcm
Peak fuel in DLOFC1,113 °C (OpenMC shape) · 1,278 °C (top-peaked)1,315 °C (OpenMC shape) · 1,483 °C (top-peaked)1,337 °C (OpenMC shape) · 1,490 °C (top-peaked)
Spent ONYX pebbles per year8,21120,52732,844
CoolantHelium, 6 MPa, 260 °C in / 750 °C out
FuelONYX pebbles, 60 mm, 9.0 g uranium at 19.75% U-235, multi-pass online refueling
Power conversion565 °C steam Rankine cycle (≈40% net, ASSUMED) or process heat and steam
ShutdownControl rods in the side reflector plus a reserve shutdown system; strong negative temperature feedback
Decay-heat removalPassive: conduction and radiation through bed, reflector and vessel to an air- or water-cooled cavity panel

Fresh-core states. In operation a CAIRN module runs near k = 1 with continuous online refueling, so only about 1,000 pcm of excess reactivity is held by the rods. A fresh core is started with a mix of fuel and graphite pebbles. Cold-shutdown margin and the reserve shutdown system are next-phase work.

Plant sizer

How many CAIRN units does your load need?

—
Recommended configuration
—
Installed electric capacity
—
ONYX pebbles discharged per year
—
Uranium (HALEU) per year

Picks the fewest identical modules that cover the demand at ≈40% net efficiency and 90% capacity factor. Fuel figures use the OpenMC discharge burnup of ONYX shown below. Directional planning numbers, not a quote.

Simulation evidence · ONYX & CAIRN

The numbers behind the claims.

Every ONYX and CAIRN figure on this page comes from our own calculations: continuous-energy Monte Carlo transport in OpenMC with ENDF/B-VIII.0 data, depletion with the ENDF/B-VIII.0 decay chain, and a 2-D transient heat-transfer model for the loss-of-cooling accident.

OpenMC slice through an ONYX pebble: thousands of coated particles in the graphite fuel zone, ringed by the SiC armour shell.
OpenMC geometry · slice through one ONYX pebble (Ø 60 mm). Each ring is a coated particle; the bright outer ring is the SiC armour.
OpenMC close-up of ONYX particles showing kernel, buffer, ZrC and SiC layers.
OpenMC geometry · close-up of particles inside the pebble (3.2 mm field). Orange kernel, dark buffer, blue ZrC, grey SiC.
OpenMC horizontal section of the CAIRN-80 core: pebble bed, graphite reflector and 18 control-rod channels.
OpenMC geometry · CAIRN-80 horizontal section: ONYX pebble bed (Ø 2.8 m), graphite side reflector, 18 control-rod channels.
OpenMC vertical section of the CAIRN-80 core.
OpenMC geometry · CAIRN-80 vertical section: 9.5 m bed, top cavity, top and bottom reflectors.
0.80.911.11.21.31.41.504080120160200240burnup (MWd per kg uranium)k∞ (infinite pebble lattice)1 / leakageONYXdischarge ≈220 MWd/kg
OpenMC depletion · k∞ of the ONYX pebble lattice versus burnup. The discharge burnup is where the burnup-averaged k∞ of a well-mixed multi-pass bed falls to the leakage line plus a 1,000 pcm control margin.
6008001000120014001600020406080100hours after loss of coolingpeak fuel temperature (°C)1,600 °C limitHTR-PM-like checkCAIRN-80CAIRN-50CAIRN-20
Accident heat transfer · peak fuel temperature after a depressurized loss of forced cooling with no pumps, no blowers and no operator action. Every CAIRN module peaks below the 1,600 °C limit for coated-particle fuel.
0246800.511.52relative power (core average = 1)height in bed (m)axial
OpenMC full core · axial fission-power profile of the fresh CAIRN-80 core (rods out).
OpenMC results · infinite pebble lattice, explicit coated particles (1σ statistical uncertainty)
CaseDescriptionk∞±1σ (pcm)Histories
ONYXONYX UN(N-15), 19.75%, 9.0 g U/pebble, 900 K1.476341050.60 M
ONYX_natNONYX with natural nitrogen (0.37% N-15)1.457261090.60 M
ONYX_Tf1200ONYX with fuel kernels at 1,200 K1.457691130.60 M
Loss of forced cooling with depressurization (DLOFC) · peak fuel temperature, no active systems
ModulePowerBed (D × H)Power densityPeak fuel, OpenMC power shapePeak fuel, top-peaked shapeTime of peakPeak vessel
CAIRN-2050 MWtØ 2.2 × 3.3 m4.0 MW/m³1,113 °C1,278 °C13 h323 °C
CAIRN-50125 MWtØ 2.6 × 6.0 m3.9 MW/m³1,315 °C1,483 °C20 h384 °C
CAIRN-80200 MWtØ 2.8 × 9.5 m3.4 MW/m³1,337 °C1,490 °C25 h392 °C
HTR-PM-like check250 MWtØ 3.0 × 11.0 m3.2 MW/m³1,524 °C1,524 °C28 h371 °C

Method and assumptions

  • Neutronics. OpenMC 0.16.0, ENDF/B-VIII.0, explicit coated particles placed by random sequential packing inside each 50 mm fuel zone, pebbles on a body-centred cubic lattice at 61% packing. Bound thermal scattering for graphite, SiC, UN and UO₂; ZrC uses free-gas scattering because no bound table exists.
  • Depletion. CE/CM predictor-corrector in the explicit-particle pebble lattice at 885 W per pebble, 228-nuclide CASL decay chain, direct reaction-rate tallies for the actinides, xenon, samarium and nitrogen. Discharge burnup uses the linear-reactivity model of a multi-pass bed, with leakage taken from the full-core CAIRN-80 model and a 1,000 pcm control margin. The reduced chain makes this estimate slightly optimistic.
  • Full core. Explicit pebbles and particles in a cylindrical bed with graphite reflectors and B4C rods in side-reflector channels; vacuum outside the reflector, which overstates leakage. Fresh-core states; the fission-power shape from these runs drives the accident model.
  • Accident heat transfer. 2-D r-z conduction and radiation, Zehner-Schlünder bed conductivity with Breitbach-Barthels radiation, Way-Wigner decay heat with a 10% margin, no convection credit. The same model gives 1,524 °C for an HTR-PM-like 250 MWt module, against published analyses near 1,500 °C.
  • Limits of this work. Conceptual-design calculations. No fuel-performance code, no coupled thermal-hydraulics, no fabrication or irradiation data for ONYX. They size the design and rank options; they do not replace testing or licensing analysis.
OpenMC 0.16.0ENDF/B-VIII.0CE/CM depletionExplicit particle packingPython r-z transientHTR-PM plausibility check

Digital core · Simulation

Every COREX is born as a digital twin.

Before we cut metal, a COREX exists as a complete multi-physics model — neutronics, heat-pipe transients, thermo-mechanics, and CFD, cross-verified and benchmarked against published experimental data. Simulation is how we de-risk the design. Testing is how we'll prove it.

Thermal field · core midplane

Coupled thermal solution — conjugate heat transfer across monolith, fuel channels, and heat-pipe bores. Illustrative animation; production CFD renders will replace this panel.

Monte Carlo transport

Neutronics — continuous-energy Monte Carlo over the full core geometry, ENDF/B-VIII.0 nuclear data. Illustrative animation · histories: 0

Heat-pipe operating envelope T → Q̇ sonic limit capillary limit boiling limit COREX design point

Heat-pipe performance — every COREX pipe is sized with margin against capillary, sonic, entrainment, and boiling limits across its full mission profile. Illustrative chart.

The toolchain

Neutronics in OpenMC and Serpent 2, cross-verified against MCNP with ENDF/B-VIII.0 data. Coupled core multi-physics in the DOE MOOSE ecosystem — Griffin for reactor physics, BISON for fuel performance, and Sockeye for heat-pipe transient behavior. Thermal-structural and CFD analysis in ANSYS and STAR-CCM+. Benchmarked against published data from the KRUSTY heat-pipe reactor test — the field's canonical validation experiment.

OpenMCSerpent 2MCNPENDF/B-VIII.0 MOOSEGriffinBISONSockeye ANSYSSTAR-CCM+KRUSTY benchmark

Simulation results characterize the conceptual design; they are a de-risking tool, not a substitute for hardware testing. Our roadmap takes the digital core to metal.

Deployment

Designed to arrive like cargo. Run like infrastructure.

01

Factory-fueled & sealed

Each COREX is designed to leave the factory fueled, tested, and sealed — no fuel handling ever happens at your site.

02

One move

Truck, rail, or barge in an ISO-class envelope. Shutdown rods locked in; decay heat rejected passively — designed to meet transport surface-temperature limits with no active cooling.

03

Set on a pad

Designed for placement on a prepared gravel pad — minimal excavation, no cooling water intake, no switchyard-scale footprint.

04

Power in days

Designed to reach full power within days of arrival — then run for years, load-following your site, with the sealed core returning to the factory at end of life.

Markets

Built for the places the grid forgot.

Remote mining

Power is up to a third of a remote mine's operating cost, hauled in as diesel over ice roads and barge seasons. A COREX is designed to power a full camp or concentrator for years per core — plus process heat.

INDEPENDENT STUDIES PROJECT NUCLEAR CUTTING REMOTE-MINE POWER COSTS BY DOUBLE-DIGIT PERCENTAGES VS DIESEL

Arctic & northern communities

Hundreds of northern communities run on diesel at the end of a thousand-kilometer supply line — among the highest electricity prices on Earth, plus heating oil on top. COREX cogeneration is designed to serve both.

REMOTE ALASKA DIESEL POWER: $0.50–$1.00+/kWh

Islands

Island grids import nearly every kilowatt-hour as fuel, exposed to price swings and storm-broken supply chains. One COREX-1200 is designed to anchor an island microgrid — with desalination heat as a by-product.

FUEL-IMPORT DEPENDENCE ≈100% ON MOST NON-INTERCONNECTED ISLANDS

Defense installations

Energy resilience is now a mission requirement. A sealed microreactor is designed to keep a base's critical loads independent of vulnerable fuel logistics and fragile local grids.

FULLY BURDENED FUEL COST IN THEATER: UP TO HUNDREDS OF $/GALLON · ≈1 CASUALTY PER 24 FUEL RESUPPLY CONVOYS (U.S. ARMY DATA)

Disaster response

After a hurricane or earthquake, generators queue for fuel that isn't coming. A transportable reactor is designed to restore hospital-scale power in days and hold it for years of rebuild — the least contested, most human use case in nuclear.

DESIGNED FOR: HOSPITAL LOADS · WATER TREATMENT · EMERGENCY SHELTER MICROGRIDS

Off-grid industry

Pipelines, telecom backbones, hydrogen pilots, remote data and research stations — steady loads in hard places, where COREX's zero-water, zero-logistics profile is designed to fit.

HEAT + POWER COGENERATION UP TO ≈600 °C-CLASS PROCESS TEMPERATURES

Diesel reality check

What is diesel really costing your site?

—
Liters of diesel per year
—
Annual fuel bill (fuel only)
—
Fuel-only cost per kWh
$0.14–0.41
NEI estimate, first-of-a-kind microreactor $/kWh — falling to $0.09–0.33 at maturity

Directional estimate only. Assumes ≈3.5 kWh per liter genset yield; excludes generator O&M, logistics, and capital on the diesel side, and reflects third-party (NEI) cost estimates — not a COREXTION price quote — on the microreactor side.

Why solid-state — COREX vs. the alternatives at a remote site
AttributeDiesel gensetsGas-cooled microreactorCOREX heat-pipe
Fuel resupplyContinuous convoys / bargesYears per coreYears per core (5–8 yr targets)
Primary coolant loop—Pressurized gas + circulatorsNone — solid-state core
Moving parts in heat removalMany, service-intensiveBlowers & circulatorsZero
Single-point cooling failuresRadiator / pump failuresCirculator class100s of independent pipes — graceful degradation
Site waterNoneNoneNone
CO₂ at site≈2.7 kg per liter burnedZeroZero
Noise & exhaustConstantMinimalMinimal — no combustion, few rotating parts

COREX columns state design intent for the conceptual COREX family. "Gas-cooled microreactor" describes the technology class generally, not any specific competitor product.

Roadmap · Where we are

From digital core to first power. In the open.

We publish our stage honestly — dated milestones behind us as fact, everything ahead of us as a target.

2026 Now

COREXTION LLC founded. COREX family conceptual design established. ONYX fuel and the CAIRN pebble-bed series defined, with OpenMC neutronics, depletion and passive-cooling studies published on this page.

2027 Target

ONYX surrogate-particle coating trials (ZrC and SiC chemical vapor deposition) and SiC-armoured pebble oxidation tests with university and national-laboratory partners. COREX-100 preliminary design freeze. Non-nuclear heat-pipe test rig — first hardware validation of the digital core. Targeting initiation of NRC pre-application engagement (Regulatory Engagement Plan).

2028 Target

Electrically heated integrated prototype — full-scale core simulator validating thermal, control, and power-conversion behavior without nuclear fuel. Applications to DOE test-bed and demonstration programs.

2029+ Target

Fueled demonstration at a national-laboratory test bed. Pilot deployments with launch partners in mining, island, and disaster-response markets.

Forward-looking targets, not commitments. Development, licensing outcomes, and timing are subject to significant uncertainty; there can be no assurance these milestones will be achieved as described or on these dates.

About COREXTION

Engineering in the open.

COREXTION LLC is a U.S. company founded in 2026 to design the COREX family of solid-state heat-pipe microreactors. We are simulation natives: our craft is taking a site's load profile and turning it into a compact, transportable reactor — rigorously, transparently, and fast.

Our transparency pledge

  • Every performance number on this site is labeled for what it is — a design target from modeling and simulation.
  • We name our codes, our data libraries, and our benchmarks, and we'll publish our methodology as we go.
  • Renders are labeled as concepts. When we have hardware, you'll see photographs.
  • Our roadmap shows targets, not promises — and we'll report the misses along with the milestones.

Contact

Tell us about your site.

Mine operator, island utility, defense energy office, relief agency, investor, or future teammate — if your problem is power in a hard place, we want the details: location, load, current fuel cost, and constraints.

Direct line: contact@corextion.com

We answer every serious inquiry. Early conversations shape the COREX-C bespoke program — the earlier you talk to us, the better the reactor fits your site.

Submitting opens a pre-filled email to contact@corextion.com in your mail app — nothing is sent until you press send there.